{"product_id":"r407h-refrigerant-commercial-refrigeration-10kg-cylinder","title":"R407H Refrigerant Commercial Refrigeration 10kg Cylinder","description":"\u003cp style=\"margin:1em 0\"\u003eR407H is an advanced HFO\/HFC blend designed for commercial and industrial refrigeration systems requiring dependable medium- and low-temperature performance. Serving as a practical, lower-GWP retrofit replacement for R404A and R507, it delivers high energy efficiency across supermarket display cases, cold storage facilities, and transport refrigeration units.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a refillable 10 kg cylinder featuring a standard 1\/4\" connection, this refrigerant ensures safe handling and straightforward recharging for routine maintenance or new equipment installations. It carries an A1 safety classification, offering non-flammable and non-toxic operation with zero ozone depletion potential.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOzone Depletion Potential (ODP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eLower than R404A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eRefillable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eEco-friendly HFO\/HFC blend with significantly lower GWP than R404A\u003c\/li\u003e\n\u003cli\u003eZero Ozone Depletion Potential (ODP = 0)\u003c\/li\u003e\n\u003cli\u003eSafety Class A1: Non-flammable and low toxicity\u003c\/li\u003e\n\u003cli\u003eSupplied in a refillable 10 kg cylinder with standard 1\/4\" connection\u003c\/li\u003e\n\u003cli\u003eOptimized for medium- and low-temperature commercial and industrial refrigeration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eMaterials \u0026amp; care\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eAlways store cylinders upright in a cool, dry, and well-ventilated space below 50 °C. Wear protective gloves and eye protection during handling to avoid direct skin contact or freeze burns from liquid refrigerant.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eSuitable as a retrofit solution for existing R404A and R507 systems in supermarket display cases, walk-in coolers, cold storage facilities, and transport refrigeration units. Compatibility with system oil, compressors, expansion valves, and seals must be verified prior to conversion.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is R407H and where is it used?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR407H is an HFO\/HFC refrigerant blend engineered as an environmentally friendly alternative to R404A. It is primarily used in commercial and industrial refrigeration, including supermarket cases, cold storage facilities, and transport cooling across medium and low temperature ranges.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R407H be used directly as a replacement for R404A?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eRetrofitting is often possible, but requires technical verification of the system. Compressors, expansion valves, seals, and oil compatibility must be evaluated by certified personnel before converting from R404A or R507.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat safety classification does R407H have?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR407H is classified under safety group A1, indicating that it is non-flammable and has low toxicity under standard operating conditions.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eHow should R407H refrigerant cylinders be stored?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eStore the cylinder upright in a cool, dry, well-ventilated area protected from direct sunlight and temperatures exceeding 50 °C, away from combustible materials.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426869575,"sku":"R407H","price":599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R407H_3d18f830-021f-44ae-bdb2-0b690813b329.jpg?v=1789251528","url":"https:\/\/momentarywatches.com\/products\/r407h-refrigerant-commercial-refrigeration-10kg-cylinder","provider":"Momentary","version":"1.0","type":"link"}