{"title":"HVAC \u0026 Air Conditioning Refrigerants","description":"Professional-grade refrigerants for heating, ventilation, and air conditioning systems, including R410A, R32, and energy-efficient replacements for residential and commercial use.","products":[{"product_id":"r410a-refrigerant-air-conditioning-cylinder-18kg","title":"R410A Refrigerant Air Conditioning Cylinder 1.8kg","description":"\u003cp style=\"margin:1em 0\"\u003eR410A refrigerant is a high-performance two-component HFC blend consisting of 50% R32 and 50% R125, engineered for reliable cooling efficiency in medium temperature ranges. It serves as an established standard refrigerant for split systems, multi-split units, VRF systems, heat pumps, and chillers.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a sealed, refillable 1.8 kg cylinder with a standard 1\/4\" connection, this refrigerant is suitable for commercial and residential air conditioning applications. Due to operating under high pressure, it is designed specifically for compatible systems and is not suitable for retrofitting older R22 equipment.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Code\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003evoll-Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eChemical Composition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR32 \/ R125 (50\/50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eCylinder Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eRefillable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eR410A refrigerant\u003c\/li\u003e\n\u003cli\u003e1800 g filling weight\u003c\/li\u003e\n\u003cli\u003eRefillable cylinder\u003c\/li\u003e\n\u003cli\u003e1\/4 connection\u003c\/li\u003e\n\u003cli\u003eHFC mixture for air conditioning technology\u003c\/li\u003e\n\u003cli\u003eSuitable for compatible air conditioning, heat pump, and chiller systems\u003c\/li\u003e\n\u003cli\u003ePerformance in the medium temperature range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with split and multi-split air conditioning units, VRF systems, heat pumps, chillers, and commercial HVAC equipment designed for R410A. Not compatible with R22 systems.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eIngredients\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003e50% Difluoromethane (HFC-32), 50% Pentafluoroethane (HFC-125).\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the chemical composition of this R410A refrigerant?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is a two-component HFC mixture consisting of 50% R32 and 50% R125.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat connection fitting does the cylinder use?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder is equipped with a standard 1\/4\" connection.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan this R410A refrigerant be used in older R22 systems?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eNo, R410A operates at high pressure and is not suitable for older R22 systems.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat systems are compatible with R410A refrigerant?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is suitable for split and multi-split air conditioners, VRF systems, heat pumps, chillers, and commercial HVAC systems.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"voll-Gas","offers":[{"title":"Default Title","offer_id":54995426476359,"sku":"R410A-1800Gr","price":149.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R410A_1800Gram.jpg?v=1789251515"},{"product_id":"r410a-refrigerant-hvac-cylinder-10kg","title":"R410A Refrigerant HVAC Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eThis R410A refrigerant is a high-performance two-component HFC blend consisting of a 50\/50 ratio of R32 and R125, engineered specifically for air conditioning, heat pump, and chiller systems. Delivering reliable performance in medium temperature ranges, it serves as a dependable standard refrigerant solution for modern climate control applications.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a factory-sealed, refillable 10 kg cylinder equipped with a standard 1\/4\" connection, it is designed for seamless integration with compatible HVAC systems. Ideal for split units, VRF systems, and commercial refrigeration, this high-pressure refrigerant ensures efficient and dependable thermal transfer.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eFill Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eComposition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR32 and R125 (50\/50 ratio)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eHFC Blend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eR410A air conditioning gas \/ refrigerant\u003c\/li\u003e\n\u003cli\u003e10 kg filling weight\u003c\/li\u003e\n\u003cli\u003eRefillable cylinder\u003c\/li\u003e\n\u003cli\u003e1\/4 connection\u003c\/li\u003e\n\u003cli\u003eHFC mixture for air conditioning technology\u003c\/li\u003e\n\u003cli\u003eSuitable for compatible air conditioning, heat pump, and chiller systems\u003c\/li\u003e\n\u003cli\u003eGood performance in the medium temperature range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with split and multi-split air conditioners, VRF systems, commercial HVAC, heat pumps, and chiller systems designed for R410A. Not compatible with R22 systems.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eIngredients\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003e50% Difluoromethane (R32), 50% Pentafluoroethane (R125).\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan I still use R410A refrigerant?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eYes, R410A remains permitted for existing systems, larger split systems, and ongoing service or maintenance.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat are the common alternatives to R410A?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eFor new installations, R32 is commonly used as a direct replacement, while R407C is used for other specific applications depending on system requirements.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat do regulations mean for an existing R410A system?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eExisting R410A systems can continue to operate, though stricter leak check requirements may apply depending on fill quantity and CO2 equivalent.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eIs R410A compatible with older R22 systems?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eNo, R410A operates at higher pressures and is not suitable for older R22 systems.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426509127,"sku":"R410A-10KG","price":399.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R410A.jpg?v=1789251516"},{"product_id":"r32-refrigerant-air-conditioning-cylinder-1-8kg","title":"R32 Refrigerant Air Conditioning Cylinder 1.8kg","description":"\u003cp style=\"margin:1em 0\"\u003eR32 is a modern, single-component HFC refrigerant offering high energy efficiency and a low global warming potential compared to legacy gases. Designed for split air conditioning units, multi-split setups, and heat pump systems, it ensures reliable cooling and heating performance while supporting compliance with modern F-gas standards.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eThis refillable 1.8 kg cylinder comes equipped with a standard 1\/4\" SAE connection, making it an ideal, convenient solution for system maintenance, servicing, and direct top-ups by qualified technicians.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Gas Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eChemical Name\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDifluoromethane (HFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\" SAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA2L (Lower Flammability, Low Toxicity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePurity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e≥99.8% (ISO 817)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e52.02 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCritical Temperature\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e78.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eEN 378, ISO 817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCool, dry, protected from direct sunlight (below 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eShelf Life\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003e3 years (sealed) from date of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eFilling weight: 1.8 kg net\u003c\/li\u003e\n\u003cli\u003eConnection type: 1\/4\" SAE (standard for modern split systems)\u003c\/li\u003e\n\u003cli\u003eContainer type: Rechargeable cylinder (reusable system)\u003c\/li\u003e\n\u003cli\u003ePure refrigerant: Simplified handling and maintenance\u003c\/li\u003e\n\u003cli\u003eSafety class A2L: Low flammability, low toxicity\u003c\/li\u003e\n\u003cli\u003eGWP value: 675 (significantly more environmentally friendly than R410A with 2088)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eMaterials \u0026amp; care\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eStore upright in a dry, well-ventilated space shielded from direct sunlight and open flames at temperatures below 50 °C. Wear safety glasses and protective gloves during handling. Certified disposal required; never vent refrigerant into the atmosphere.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with systems engineered specifically for R32 refrigerant, including:\u003c\/p\u003e\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eSplit and multi-split air conditioning units\u003c\/li\u003e\n\u003cli\u003eVariable Refrigerant Flow (VRF) commercial systems\u003c\/li\u003e\n\u003cli\u003eAir-to-air heat pumps designed for heating and cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R32 refrigerant be used in an R410A system?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eNo. R32 requires systems and components engineered specifically for its operating characteristics and A2L safety classification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat connection does this cylinder use?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder features a standard 1\/4\" SAE connection commonly used for modern split air conditioning systems.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R32 be recharged by non-professionals?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eRefrigerant handling and charging should only be performed by certified HVAC technicians in accordance with local F-gas regulations and safety standards.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat are the storage requirements for this cylinder?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eStore upright in a cool, dry area away from direct sunlight, ignition sources, and temperatures exceeding 50 °C, ensuring the cylinder is secured against falling.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426541895,"sku":"R32-1800Gr","price":149.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R32_1800gr.jpg?v=1789251519"},{"product_id":"r32-refrigerant-split-air-conditioning-cylinder-9kg","title":"R32 Refrigerant Split Air Conditioning Cylinder 9kg","description":"\u003cp style=\"margin:1em 0\"\u003eR32 is a high-performance refrigerant designed for modern split air conditioning systems and heat pumps, delivering superior energy efficiency and a low global warming potential of 675. As a single-component hydrofluorocarbon, it simplifies servicing and maintenance while meeting current F-gas regulatory standards.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a 9kg rechargeable cylinder with a standard 1\/4\" connection, this A2L-classified refrigerant ensures reliable operation and cost-effective cooling performance for residential and commercial HVAC applications.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR32 (Difluoromethane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA2L (Mildly Flammable \/ Low Toxicity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRechargeable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eSplit Air Conditioning, Multi-Split, Heat Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eHigh energy efficiency with a low Global Warming Potential (GWP) of 675\u003c\/li\u003e\n\u003cli\u003eSingle-substance refrigerant for easier handling, charging, and maintenance\u003c\/li\u003e\n\u003cli\u003eSafety classified A2L (mildly flammable, low toxicity)\u003c\/li\u003e\n\u003cli\u003eStandard 1\/4\" connection compatible with modern HVAC equipment\u003c\/li\u003e\n\u003cli\u003eIdeal for split, multi-split air conditioning systems and heat pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003ch2\u003eR32 vs. R32A: Compatibility Notes\u003c\/h2\u003e\u003cp style=\"margin:1em 0\"\u003eThe designations R32 and R32A are often used synonymously; chemically, they are the same substance (difluoromethane). The suffix \"A\" in the designation is used in some markets to identify it as a pure substance or refers to specific product variants from individual manufacturers. In practice, both designations are compatible, provided that the purity and specifications match.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eWhen selecting, pay attention to the exact product designation and the information in the safety data sheet. Some manufacturers use the designation R32 for specific container sizes or applications. It is crucial that the refrigerant complies with the EN 378 and ISO 817 standards and is approved for the respective system. Only refrigerant that is approved for use in A2L systems must be used.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eCompatibility concerns not only the refrigerant itself but also the components used: seals, hoses, and connections must be suitable for R32. Older systems designed for R410A or R407C generally cannot be easily converted to R32. A conversion requires a technical inspection and, if necessary, the replacement of components.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the difference between R32 and R32A?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eChemically, they are the same substance (difluoromethane). The R32A designation is sometimes used to denote pure single-substance status or specific manufacturer variations.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat safety classification does R32 refrigerant have?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR32 is classified under safety group A2L, meaning it has low toxicity and is mildly flammable, requiring standard safety precautions and adequate ventilation during handling.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan older R410A or R407C systems be converted to R32?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eOlder systems designed for R410A or R407C generally cannot be switched to R32 directly, as components, seals, and fittings must be specifically certified for A2L refrigerants.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eHow should R32 refrigerant cylinders be stored?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eCylinders should be stored upright in cool, well-ventilated, dry areas away from direct sunlight, heat sources, and combustible materials.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426607431,"sku":"R32-9KG","price":399.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R32_9Kg.jpg?v=1789251520"},{"product_id":"r407c-refrigerant-air-conditioning-cylinder-10kg","title":"R407C Refrigerant Air Conditioning Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR407C is an established HFC refrigerant blend designed for air conditioning systems, heat pumps, and commercial refrigeration applications, offering dependable R22-comparable performance. Supplied in a rechargeable 10kg cylinder with a standard 1\/4\" connection, it delivers an effective and proven retrofit solution for existing R22 installations as well as new commercial setups.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eFeaturing zero ozone depletion potential and an A1 non-flammable safety classification, this ternary blend ensures broad system compatibility across split systems, VRF units, and residential or commercial heat pumps. Its reliable formulation provides efficient cooling capacity and stable operating characteristics when properly charged in the liquid phase.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eFilling Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eComposition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR32\/R125\/R134a (23\/25\/52%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e~1774\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eTemperature Glide\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e~5–7 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eOzone Depletion Potential (ODP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eEN 378, ISO 817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eHFC Blend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eZero ozone depletion potential (ODP = 0) with an A1 non-flammable safety rating\u003c\/li\u003e\n\u003cli\u003eDirect retrofit capability for R22 air conditioning and heat pump systems\u003c\/li\u003e\n\u003cli\u003eSupplied in a durable, rechargeable 10kg cylinder with a 1\/4\" valve connection\u003c\/li\u003e\n\u003cli\u003eTernary HFC formulation (R32\/R125\/R134a) engineered for medium-temperature applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with split systems, VRF systems, residential and commercial heat pumps, and cold rooms. Requires polyolester (POE) lubricant when retrofitting systems previously operated with R22 mineral oil.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHow to use\u003c\/h3\u003e\n\u003ch2\u003eR407C as a retrofit solution for R22 systems\u003c\/h2\u003e\u003cp style=\"margin:1em 0\"\u003eR407C was specifically developed for the retrofitting of existing R22 systems. The performance data is similar to R22, which allows for a direct replacement in many systems. Typical procedure:\u003c\/p\u003e\u003col style=\"margin:1em 0\"\u003e\n\u003cli\u003eRecover R22 completely.\u003c\/li\u003e\n\u003cli\u003eReplace mineral oil with polyolester (POE) in 2–3 cycles, as R407C is not compatible with mineral oil.\u003c\/li\u003e\n\u003cli\u003eReplace the filter drier with an HFC\/POE-compatible model.\u003c\/li\u003e\n\u003cli\u003eEvacuate the system to remove moisture and foreign gases.\u003c\/li\u003e\n\u003cli\u003eCharge R407C in liquid form according to the manufacturer's weight – do not mix with R22 residues.\u003c\/li\u003e\n\u003cli\u003eCheck for leaks as well as superheat\/subcooling.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp style=\"margin:1em 0\"\u003eThe temperature glide of ~5–7 K is a significant difference compared to pure refrigerants like R32. It influences the design of heat exchangers and expansion valves. Before any retrofit, the system must be professionally inspected. Only refrigerant that complies with the EN 378 and ISO 817 standards must be used.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is R407C and what systems is it used for?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR407C is a ternary HFC refrigerant blend consisting of R32, R125, and R134a. It is primarily used in air conditioning units, heat pumps, and medium-temperature commercial refrigeration systems.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R407C be used as a direct replacement for R22?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt serves as a retrofit replacement for R22 systems, requiring an oil change from mineral oil to polyolester (POE) oil and a system check to verify component compatibility.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhy must R407C be charged in the liquid phase?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eBecause R407C is a zeotropic blend with a temperature glide of approximately 5–7 K, charging it from the vapour phase causes fractionation and alters the refrigerant composition.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eHow should the R407C cylinder be stored safely?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eStore the cylinder upright in a cool, dry area away from direct sunlight, heat sources exceeding 50 °C, and combustible materials, securing it against falling.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426902343,"sku":"R407C-10KG","price":399.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R407C.jpg?v=1789251528"},{"product_id":"r417a-refrigerant-air-conditioning-cylinder-10kg","title":"R417A Refrigerant Air Conditioning Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR417A is a proven HFC refrigerant blend designed as an effective drop-in replacement for R22 in existing air conditioning and refrigeration systems. Supplied in a 10 kg refillable cylinder with a standard 1\/4\" connection, it delivers reliable cooling performance for commercial and industrial applications.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eFeaturing an A1 safety classification, this non-flammable and non-toxic refrigerant offers an ozone depletion potential of zero. It is ideal for split air conditioners, VRF systems, and medium-temperature refrigeration equipment undergoing retrofits or regular maintenance.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eHFC Blend (R125, R134a, R600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eFill Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCylinder Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable Cylinder (Reusable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA1 (Non-flammable, low toxicity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eapprox. 2346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eODP (Ozone Depletion Potential)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eApplication Area\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eAir conditioning, refrigeration systems, R22 retrofit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eDrop-in R22 replacement for existing HVAC and refrigeration systems\u003c\/li\u003e\n\u003cli\u003eRefillable 10 kg cylinder with standard 1\/4\" valve fitting\u003c\/li\u003e\n\u003cli\u003eA1 safety classification: non-flammable and non-toxic\u003c\/li\u003e\n\u003cli\u003eZero Ozone Depletion Potential (ODP = 0)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with existing R22 air conditioning and refrigeration installations, including split air conditioning units, VRF systems, and medium-temperature commercial refrigeration equipment.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eIngredients\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003ePentafluoroethane (R125)\u003c\/li\u003e\n\u003cli\u003e1,1,1,2-Tetrafluoroethane (R134a)\u003c\/li\u003e\n\u003cli\u003eButane (R600)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R417A replace R22?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eYes, R417A serves as a direct drop-in replacement for R22 in existing air conditioning and refrigeration systems without requiring complete system replacement.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is R417A refrigerant composed of?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR417A is an HFC blend formulated from R125, R134a, and R600, designed specifically to replace HCFC R22.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the safety classification of R417A?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR417A has an A1 safety rating, indicating that it is non-flammable and exhibits low toxicity.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat connection does the cylinder use?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe 10 kg refillable cylinder comes equipped with a standard 1\/4\" connection.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426935111,"sku":"R417A","price":599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R417A_10kg.jpg?v=1789251532"},{"product_id":"r455a-refrigerant-commercial-refrigeration-cylinder-10kg","title":"R455A Refrigerant Commercial Refrigeration Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR455A refrigerant gas mixture designed for commercial and industrial refrigeration systems as well as compatible HVAC applications. Supplied as brand-new, factory-sealed product in a refillable cylinder containing 10 kg of refrigerant.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eThe returnable cylinder is equipped with a standard 1\/4\" connection port and includes return documentation for professional refilling and exchange.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR455A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCylinder Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eValve Connection\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand New, Factory Sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eCommercial refrigeration, industrial cooling systems, compatible HVAC equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003ePre-filled with 10 kg of high-performance R455A refrigerant\u003c\/li\u003e\n\u003cli\u003eRefillable and returnable cylinder design included\u003c\/li\u003e\n\u003cli\u003eStandard 1\/4\" valve connection for broad system compatibility\u003c\/li\u003e\n\u003cli\u003eSupplied brand-new in original sealed condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with commercial and industrial refrigeration systems as well as HVAC setups designed for R455A refrigerant blends with a standard 1\/4\" connection.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the net filling weight of the cylinder?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder contains 10 kg of R455A refrigerant.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat valve connection size does this cylinder use?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder features a standard 1\/4\" connection port.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan this refrigerant cylinder be refilled?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eYes, this is a refillable cylinder that can be returned for refills using the included return documentation.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat applications is R455A suitable for?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR455A is formulated for commercial refrigeration, industrial cooling systems, and compatible HVAC installations.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995426967879,"sku":"R455A","price":699.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R455A.jpg?v=1789251533"},{"product_id":"r450a-refrigerant-low-gwp-cylinder-10kg","title":"R450A Refrigerant Low GWP Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR450A refrigerant is an advanced HFO\/HFC blend engineered as an efficient, low-GWP replacement for R134a. Formulated for commercial and industrial refrigeration as well as HVAC systems, it delivers comparable thermal performance with a substantially lower environmental impact.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a factory-sealed 10 kg refillable cylinder with a standard 1\/4\" connection, this refrigerant is ideal for cold storage, supermarket display cases, and system retrofit projects.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003evoll-Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR450A (HFO\/HFC blend)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eFill Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCylinder Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eLower than R134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eTarget Applications\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eCommercial refrigeration, cold rooms, supermarket display cases, HVAC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eR450A refrigerant\u003c\/li\u003e\n\u003cli\u003e10 kg filling weight\u003c\/li\u003e\n\u003cli\u003eRefillable cylinder\u003c\/li\u003e\n\u003cli\u003e1\/4 inch connection\u003c\/li\u003e\n\u003cli\u003eAlternative to R134a\u003c\/li\u003e\n\u003cli\u003eLower GWP compared to R134a\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial refrigeration and air conditioning applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with commercial refrigeration systems, cold storage rooms, supermarket display cases, industrial chillers, and HVAC units designed or approved for R450A, including retrofit projects for compatible R134a systems.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is R450A refrigerant used for?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR450A is an HFO\/HFC blend designed as a lower-GWP alternative to R134a for commercial refrigeration, cold storage, display cases, industrial cooling, and HVAC retrofit applications.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat size and type of cylinder is included?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is supplied in a sealed 10 kg refillable cylinder equipped with a standard 1\/4\" valve connection.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan the empty cylinder be returned for refilling?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eYes, containers can be returned for refilling in accordance with EU regulations using the included return slip.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWho is eligible to purchase this refrigerant?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eSale is restricted to certified personnel or companies employing qualified technicians in compliance with Regulation (EU) 2024\/573 for installation, maintenance, and repair.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"voll-Gas","offers":[{"title":"Default Title","offer_id":54995427000647,"sku":"R450A-10KG","price":699.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R450A.jpg?v=1789251533"},{"product_id":"r454b-refrigerant-commercial-refrigeration-cylinder-10kg","title":"R454B Refrigerant Commercial Refrigeration Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR454B refrigerant is an eco-friendly HFO\/HFC blend formulated with a low Global Warming Potential (GWP) as an efficient alternative to R410A. It delivers comparable thermodynamic performance with approximately 78% lower GWP, making it ideal for sustainable climate control solutions.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a sealed 10kg refillable cylinder included in the purchase, this refrigerant is suitable for residential and commercial heat pumps, air conditioning systems, VRF\/VRV units, and medium-temperature commercial refrigeration.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eChemical Composition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eHFO\/HFC Blend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGlobal Warming Potential (GWP)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eApprox. 78% lower than R410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eRefillable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eEco-friendly HFO\/HFC blend with low Global Warming Potential\u003c\/li\u003e\n\u003cli\u003eApproximately 78% lower GWP compared to R410A\u003c\/li\u003e\n\u003cli\u003eHigh energy efficiency for cooling and heating applications\u003c\/li\u003e\n\u003cli\u003eSupplied in an original sealed 10kg returnable cylinder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eSuitable for residential and commercial split and multi-split air conditioning, VRF\/VRV systems, heat pumps, and medium-temperature commercial refrigeration units designed for R454B.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is R454B refrigerant designed to replace?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR454B is designed as a low-GWP alternative to R410A, offering comparable performance with approximately 78% lower Global Warming Potential.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eIs the cylinder included in the price?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eYes, the sealed cylinder is included in the purchase price.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat are the primary applications for R454B?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is used in residential and commercial split\/multi-split air conditioning systems, VRF\/VRV units, heat pumps, and medium-temperature refrigeration equipment.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the net weight of refrigerant in this cylinder?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder contains 10kg of R454B refrigerant.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Momentary","offers":[{"title":"Default Title","offer_id":54995427623239,"sku":"R454B","price":699.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R454B_10kg.jpg?v=1789251537"},{"product_id":"r513a-refrigerant-chiller-gas-cylinder-10kg","title":"R513A Refrigerant Chiller Gas Cylinder 10kg","description":"\u003cp style=\"margin:1em 0\"\u003eR513A refrigerant is an HFO\/HFC blend designed as an eco-friendly alternative to R134a in commercial refrigeration and chiller systems. With a significantly lower GWP rating of 630 and zero ODP, it delivers reliable performance while meeting modern F-gas standards.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eSupplied in a refillable 10kg cylinder with a standard 1\/4\" SAE connection, this non-flammable A1 safety class refrigerant is ideal for servicing, retrofitting, and maintaining medium-temperature refrigeration systems.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003evoll-Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eR513A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eConnection Size\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1\/4\" SAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eContainer Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRefillable Cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eComposition\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eHFO\/HFC blend (R1234yf + R134a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMix Ratio\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eapprox. 56% \/ 44%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePurity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e≥99.0% (ISO 817)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eGWP (Global Warming Potential)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eODP (Ozone Depletion Potential)\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eA1 (Non-flammable, non-toxic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003eCool, dry place protected from sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eFilling weight: 10 kg net (gross weight)\u003c\/li\u003e\n\u003cli\u003eConnection type: 1\/4 inch (SAE connection) — standard for commercial systems\u003c\/li\u003e\n\u003cli\u003eContainer type: Rechargeable cylinder (returnable system)\u003c\/li\u003e\n\u003cli\u003eComposition: HFO\/HFC blend (R1234yf + R134a, approx. 56% \/ 44%)\u003c\/li\u003e\n\u003cli\u003eGWP value: 630 (significantly lower than R134a with 1430)\u003c\/li\u003e\n\u003cli\u003eSafety class A1: Non-flammable, non-toxic\u003c\/li\u003e\n\u003cli\u003eDrop-in replacement: Compatible with R134a systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eMaterials \u0026amp; care\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eStore upright in a cool, dry area away from direct sunlight. Handle according to standard refrigeration safety procedures and ensure recovery and disposal are handled through certified recycling facilities.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with commercial refrigeration units, medium-temperature cooling cabinets, supermarket display cases, cold rooms, heat pumps, and water- or air-cooled chiller systems designed for R134a retrofit or original R513A operation.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eCan R513A be used directly in an existing R134a system?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR513A serves as a retrofit replacement for R134a systems, but installation requires professional inspection and potential system adjustments by a qualified technician.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the safety classification of R513A refrigerant?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eR513A is classified under safety group A1, meaning it is non-flammable and non-toxic under normal operating conditions.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat connection does this cylinder use?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe cylinder is equipped with a standard 1\/4\" SAE valve connection suitable for commercial refrigeration equipment.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the chemical composition of R513A?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is an HFO\/HFC blend composed of approximately 56% R1234yf and 44% R134a with a purity of 99.0% or higher.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"voll-Gas","offers":[{"title":"Default Title","offer_id":54995427721543,"sku":"R513A","price":599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1004\/7579\/7831\/files\/R513A.jpg?v=1789251542"}],"url":"https:\/\/momentarywatches.com\/collections\/hvac-air-conditioning.oembed","provider":"Momentary","version":"1.0","type":"link"}